MicroLog works with the following external sensors:
DT132 (2.5m) External Temperature Sensor
This MicroLog sensor takes external temperature measurements in a wider range than the internal temperature sensor. With a faster response time than the internal sensor, it enables measuring materials that cannot be measured with the internal sensor.
Specifications:
| Range: |
-50 °C to 100 °C |
| Resolution: |
Better than 2 °C |
| Accuracy: |
± 2% of reading |
| Probe Length: |
100 mm |
| Probe OD: |
3.2 mm |
| Max. Temperature: |
150 °C |
Download External Temperature Sensor PDF file

DT093 External Temperature Sensor with 8m Probe
| Range: |
-50 °C to 100 °C |
| Resolution: |
Better than 2 °C |
| Accuracy: |
±2% of reading |
| Probe Length: |
100 mm |
| Probe OD: |
3.2 mm |
| Max. Temperature: |
100 °C |

DT140 0-10 Volt Sensor
A general sensor that will measure any device or transmitter that produces a linear analog 0-10V output. The voltage can easily be converted to the correct measured units with the help of the Microlab program.
Specifications:
| Range: |
0-10 V |
| Resolution: |
0.05 V |
| Accuracy: |
± 3% before calibration |
| Input Impedance: |
3 M |
| Calibration: |
Two point calibration |
| OV Protection: |
+30 V |
Download 0-10 Volt Sensor PDF file

DT139 0-20 mAmp External Sensor
This MicroLog external sensor can sample any device or transmitter, producing a linear current between 0-20 mAmp. The 0-20 mAmp can be converted to the correct measured units by using Microlab¹s calibration option.
Specifications:
DT141 External Contact Adapter
This MicroLog sensor monitors Reed Relay contacts and switch status (open/closed), to identify the correlation between phenomena such as temperature change and door status.
Specifications:
| Range: |
Open/Close |
| Connector: |
Screw Terminal |
| Cable Length: |
2.5 m |
| Internal Pull-Up Resistor: |
No need for external power source |
Download External Contact Adapter PDF file
DT168 External pH Adaptor
| Range: |
0-14 pH |
| Resolution: |
0.116 pH |
| Accuracy: |
5% of reading |
| Calibration: |
Offset calibration |

External PT100 Temperature Adaptor
| Range: |
-10 °C to 10 °C /
-100 °C to 120 °C
|
| Resolution: |
0.1 °C / 1.1 °C |
| Accuracy: |
± 0.25 °C / ± 1°C |
| Connector: |
Screw Terminal |

DT279 Conductivity Adapter and Electrode
| Range: |
0–20 mS |
| Resolution: |
0.04 mS |
| Accuracy: |
3% |
| Response Time: |
Less than 1 minute |

DT163 Light
Light Range:
|
0 - 5000 Lux
|
| Resolution: |
25 Lux |
| Accuracy: |
20% of reading |
|